Gamepad user interface
Normal operation
During normal operation the main screen on the 2.4 inch display shows an overview of the selected profile settings and key bindings. By pressing the select key of the thumb key row you can toggle through the different modes.
During normal operation the individual main screen will be shown. Elements of and areas of the main screen are described in the following two figures.
Select profile mode
Change the profile in this mode. Use the 5-way digital stick up and down to select the desired profile and confirm your choice by pressing the center button of the stick.
You can switch to the next mode at any time by pressing the select key.
Configuration mode
The configuration menu gives you the options as shown below. If connected to the network you can find here also the ip adresse and links for the web-configuration.
By pressing the select button again can switch back the the normal operation mode.
-
Connect WIFI: Allows you to connect with the WIFI network. It tries to connect to the saved network. If the connection cannot establish it is going into the network configuration mode and establish an accesses point with the SSID “MyGamepad”.
-
Disconnect WIFI: Disconnects the device from the network. The web configuration interface is not accessible anymore.
-
Analog-Stick calibration: Starts the analog stick calibration process. See below.
-
Reset WIFI settings: Deletes the saved WIFI settings. Use this in case you want to switch the network.
-
Restart device: Reboots the device.
-
Factory settings: Deletes all profile and WIFI settings.
-
Switch setup to right hand: Sets the left/right hand mode
-
About: Shows information about the device.
Analog stick calibration
With this function you can calibrate the analog stick in 3 simple steps. You can leave this mode at any time by using the select key.
Step 1 – Define the new center values
Leave the analog stick untouched in the center and press the DPAD center button to confirm.
Step 2 – Define the new center values
In this step, simply circle the stick 2 – 3 times in all direction as far as possible and hold it as long as the values are changing.
As soon as the min./max. values no longer change while circling around in all direction, press the DPAD center button to proceed to step 3.
Step 3 – Test the new values
In this step, you can validate the new values. While the analog stick is centered, the X and Y values must be around 2047, typically ±50. When moving the stick, the values in both dimensions should be in the range from 0 to 4095.
By pressing the DPAD center button, the new calibration values are saved in the device and the process is completed (see figure below).